Komatsu — eebm001902 a3.pdf

TESTING AND ADJUSTING ADJUSTMENT OF FLOW CONTROL SYSTEM 6. Once the controller setting has been changed, fully depress and hold down the RH attachment pedal. Take note of the steady pressure reading then adjust the controller output (as described in 5 above) again if necessary. It is important that the foot pedal is re- leased between pressure checks otherwise the gauge will not give a true reading. Repeat this process until the measured PPC pressure is within 5% of the required value. Use fig (i) to establish the PPC pres- sure required to generate the desired oil flow rate. Note: The adjustment screw allows the controller output to be varied by ± 10%.

The effect of the adjust- ment operates on all of the controller switch set- tings (ie a 5% adjustment alters all o the switch settings by 5%). 7. After correctly setting the controller output, tighten the lock-nut on the controller to prevent the setting from changing during operation of the machine. Replace the rear panel. Remove the pressure gauge. 20-48