TESTING AND ADJUSTING TESTING LOCATIONS CAUSING HYDRAULIC DRIFT OF WORK EQUIPMENT TESTING LOCATIONS CAUSING HYDRAULIC DRIFT OF WORK EQUIPMENT # If there is any hydraulic drift in the work equipment (cylinders), check as follows to determine if the cause is in the cylinder packing or in the control valve. 1. Checking for defective cylinder packing. a. Checking boom and bucket cylinders. i. Set in the same posture as when measuring hydraulic drift, and stop the engine. ii. Operate the boom control lever to RAISE or the bucket control lever to CURL. If the low- ering speed increases, the packing is defec- tive.

If there is no change, the boom holding valve (boom) or the control valve (bucket) is defective. b. Checking arm cylinder. i. Operate the arm cylinder to move the arm in fully, then stop the engine. ii. Operate the control lever to arm IN. If the lowering speed increases, the packing is de- fective. If there is no change, the control valve is defective. # If the pressure in the accumulator has dropped, run the engine for approximately 10 seconds to change the accumulator again before operating. 2268 kg Reference: If the cause of the hydraulic drift is in the packing, and the above operations are car- ried out, the downward movement becomes faster for the following reasons. 1.

If the work equipment is set to the above posture (holding pressure applied to the bottom end), the oil at the bottom end leaks to the head end. However, the volume at the end is smaller than the volume at the bottom end by the volume of the rod, so the internal pressure at the head end increases because of the oil flowing in from the bottom end. 2. When the internal pressure at the head end increases, the pressure at the bottom end also rises in proportion to this. The balance is maintained at a certain pres- sure (this differs according to the amount of leakage) by repeating this procedure. 3. When the pressure is balanced, the downward move- ment becomes slower.

If the lever is then operated according to the procedure given above, the circuit at the head end is opened to the drain circuit (the bottom end is closed by check valve), so the oil at the head end flows to the drain circuit and the downward move- ment becomes faster. 20-51