TESTING AND ADJUSTING TESTING LOCATIONS CAUSING HYDRAULIC DRIFT OF WORK EQUIPMENT 2. Checking boom holding valve. Set the work equipment at the maximum reach, and the top of the boom horizontal, then stop the engine. a. Lock the work equipment control levers and re- lease the pressure inside the hydraulic tank. i. Disconnect pilot hose (1) of the boom hold- ing valve, and install a blind plug in the hose. # Blind plug: 07376-50315 # Leave the boom holding valve end open. # If any oil leaks from the port that is left open, the boom holding valve is defective. 3. Checking the PPC valve a.
If the hydraulic drift differs when the safety lock le- ver is in the LOCK or FREE position, (engine running), the PPC valve is defective. 20-52