TESTING AND ADJUSTING POINTS TO REMEMBER WHEN CARRYING OUT MAINTENANCE TROUBLESHOOTING v. Oil or dirt stuck to connector. If oil or grease is stuck to the connector and an oil film is formed on the mating surface between the male and female pins, the oil will not let the electricity pass, so there will be defective contact. If there is oil or grease stuck to the connector, wipe it off with a dry cloth or blow dry with compressed air and spray it with a contact restorer. # When wiping the mating portion of the connector, be careful not to use excessive force or deform the pins.
# If there is oil or water in the compressed air, the con- tacts will become even dirtier, so remove the oil and water from the compressed air completely before cleaning with compressed air. 2. Removing, installing, and drying connectors and wir- ing harnesses. a. Disconnecting connectors i. Hold the connectors when disconnecting. When disconnecting the connectors, hold the connectors and not the wires. For con- nectors held by a screw, loosen the screw fully, then hold the male and female connec- tors in each hand and pull apart. For connec- tors which have a lock stopper, press down the stopper with your thumb and pull the con- nectors apart. # Never pull with one hand. b.
When removing from clips i. When removing a connector from a clip, pull the connector in a parallel direction to the clip. # If the connector is twisted up and down or to the left or right, the housing may break. 20-62