TROUBLESHOOTING DISPLAY METHOD AND SPECIAL FUNCTIONS OF MONITOR PANEL d. Display of trouble data The monitor panel records both service codes which are included in the user code and service codes which are not included. This data can be displayed on the time display as follows. # For details of the service codes that are not included in the user code, see ACTION TAKEN BY CONTROL- LER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE or the JUDGEMENT TABLE. i) Method of displaying trouble data 20-84 Operation Display 1. To set to the trouble data display mode, keep the TIME switch + L.H. travel speed switch pressed for 2.5 seconds. Note: It is possible to call it up at the fol- lowing tiems.
1) In the normal mode. 2) In the user code display mode. 3) In the machine data monitoring mode. 4) In the time adjustment mode. 2. To go to the next service code display, press the time switch + R.H. working mode switch. 3. To go back to the previous service code display, press time switch + L.H. work- ing mode switch. 1. On the time display and service meter display, the service code and number of hours (service meter hours) that have elapsed since the occurrence of the abnormality are displayed. • Example of display: When E212 has occurred 12 hours before (service meter). 1) Display of service code and elapsed time 2) If any abnormality exists at this time, the E mark is displayed.