Komatsu — eebm001902 a3.pdf

TROUBLESHOOTING DETAILS OF TROUBLESHOOTING AND TROUBLESHOOTING PROCEDURE DETAILS OF TROUBLESHOOTING AND TROUBLESHOOTING PROCEDURE If there is a failure in the excavator, use the following procedure to determine which troubleshooting chart to use to repair the failure. When carrying out troubleshooting, ask the operator as much as possible about the condition of the machine, and check the following items before starting. 1. Condition of controller connection (check with monitoring codes 02 - 03). The display should read 02:290 and 03:290. If not, check the model selection connector C09 and compare with the electrical schematic.

If monitoring codes 02 - 03 read “- - -“, continue with the following step. 2. Blown fuses. 3. Battery voltage (monitoring code 32). If the voltage is outside the standard range (see Standard Judgement Table), carry out Troubleshooting Chart E-1. 4. Electricity generation (charge input) voltage (monitoring code 43). The procedure for carrying out check item No. 3 is in Step 1a. and check item No. 4 begins at Step 1b. on the following pages. 20-96