TROUBLESHOOTING E-MODE 20-107 User code Service code Abnormal system Nature of abnormality - E306 Abnormality in feedback potentiometer system 1. Short circuit in wiring harness between C03 (7) - (14), (7) - (17), (14) - (17) 2. Short circuit in wiring harness between E04 (1) - (2), (1) - (3), (2) - (3) 3. Short circuit in wiring harness between E06 (1) - (2), (10 - (3), (2) - (3) 4. Short circuit in wiring harness between C03 (7) - (4), (4) - (17) 5. Disconnection in wiring harness between C03 (7) - E04 (1) 6. Disconnection in wiring harness between C03 (14) - E04 (2) 7. Disconnection in wiring harness between C03 (17) - E04 (3) 8. Defective governor motor potentiometer 9.
Defective contact of C03, E04 connectors - E315 Abnormality (short circuit) in battery relay output system If excess current flows between C03 (1) and battery relay # This occurs only when turning starting switch to OFF and stopping engine - E316 Abnormality (step-out) in motor 1. Defective adjustment of rod or scuffing of loose spring 2. Abnormality in governor motor 33.. AAbbnnoorrmmaalliittyy iinn egnogvienneo trh, rpouttmlep • cpounmtrpo llceorntroller