TROUBLESHOOTING C-MODE C-10 [E206] Short circuit in travel speed solenoid system is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if an E service code is not displayed, the problem has been removed. # If the starting switch is turned OFF after an abnormality occurs, turn the starting switch ON and check if an e service code is displayed. (If it is not displayed, the problem had been removed). # Before carrying out troubleshooting, check that all related connectors are properly inserted.
# Always connect any disconnected connectors before going on the next step. at Hi or Mi. Operate the lever slightly but not enough to move the machine. Table 1 C-10 Related electric circuit diagram A07 (KESI) 20-184 3 YES Is resistance YES between C01 2 (female) (2) and Is resistance chassis normal? YES b (1e )t w ane de n (2 V ),0 (3 2 ( )m aa nl de) • Turn starting switch NO 1 chassis as shown in OFF. Table 1? • Disconnect C01 Interchange • 20 - 60 q • Turn starting switch connector with other OFF. NO solenoid. Is [E206] • Disconnect V06 displayed? • Turn starting switch OFF. • Interchange V06 with NO other connector.
• Start engine • Travel speed switch Cause Remedy Defective engine throttle • pump controller Short circuit with chassis ground in wiring harness between C01 (female) (8) and V06 (female) (2) Defective pump merge/divider solenoid (internal short circuit or short circuit with ground) Replace Repair or replace Replace BetweenVV0063(male)(1)-(2) 20-60q BetweenV063(male)(2)-chassis Min.1Mq