TROUBLESHOOTING H-MODE H-9 Bucket is slow or lacks power # When travel and swing speeds are normal. Note 1: If the auto-deceleration is canceled when bucket CURL or bucket DUMP is operated, the system is normal. Note 2: After inspection, do not forget to return the interchanged valves to the original position. 20-221 3 YES Go to A Does control valve YES spool for bucket 2 move smoothly? YES Is output pressure of NO PPC valve normal? 1 • Min. 2.7 MPa Is pressure switch for bucket CURL, DUMP (28 kg/cm2) NO • Engine at high idling normal? • Operate bucket. • See Judgement Table. (Bit pattern 21 (1), (2)) NO • See Not 1. 5 YES YES Is leakage from 4 bucket cylinder normal?
Is pressure compensation valve for • Max. 20 cc/min NO From A bucket normal, or does • Engine at high idling pressure compensation piston move smoothly? • It is also possible to interchange with NO other compensation valve. • See Note 2. Cause Remedy Defective operation of control valve spool for bucket Defective PPC valve Defective bucket CURL or bucket DUMP pressure switch Defective operation of safety-suction valve for bucket Defective bucket cylinder piston packing Defective operation of pressure compensation valve for bucket or pressure compensation piston Correct or replace Replace Repalce Repair or replace Repair or replace Repair or replace