Komatsu — eebm001902 a3.pdf

TROUBLESHOOTING H-MODE H-22 Travel speed does not switch or is faster than specified speed # Carry out troubleshooting in the H/O mode Table 1 Output pressure of LS control EPC valve H-23 Travel does not move (one side only) 20-233 Lo Mi Hi PC290 1.9 ± 0.2 MPa (19 ± 2 kg/cm2) 1.9 ± 0.2 MPa (19 ± 2 kg/cm2) 0.2 ± 0.2 MPa / 3.0 ± 3.0 MPa (2 ± 2 kg/cm2) / (30 ± 2 kg/cm2) Remarks • Engine at high idling • Travel lever at Fine control position (auto-deceleration canceled) 3 YES Is output pressure of YES travel speed selector 1 solenoid valve normal? Is any dirt found in NO final drive drain? 2 Is drain amount of NO travel motor normal? • Max: 30 l/min.

• Engine at high idling Cause Remedy Defective final drive Defective operation of suction valve of control valve Defective conterbalance valve, or detective operation of travel motor safety valve Defective travel motor Repair or replace Replace Replace Replace