TROUBLESHOOTING H-MODE H-24 Does not swing b) Does not swing in one direction 20-234 a) Does not swing to either left or right 3 YES Is any foreign material found in oil drained 2 from swing machinery? Is output pressure of YES swing holding brake NO solenoid valve normal? 1 • Min 2.74 MPa (28 kg/ cm2) NO Is swing pressure • Operate swing lever switch normal? (or operate work equipment lever.) • See JUDGEMENT TABLE (bit pattern 20 (2)). • Note: If auto- NO deceleration is canceled when travel is operated, system is normal.
Cause Remedy Defective swing machinery Repair or replace Defective swing holding Repair or brake or swing motor replace Defective operation of Correct or holding brake solenoid valve replace Defective swing pressure Replace switch YES 2 Does control valve YES spool for swing move smoothly 1 NO Is PPC valve output pressure normal? • Min 2.74 MPa (28 kg/ cm2) • Operate swing lever (or operate work NO equipment lever.) Cause Remedy Defective swing motor Replace safety valve or suction valve Defective operation of Correct or control valve spool for swing replace Defective PPC valve Replace