TROUBLESHOOTING H-MODE b) When swing holding brake is applied H-30 Swing speed is faster than specified speed in L/O and F/O modes # Carry out troubleshooting in the H/O mode. Table 1 Output pressure of LS control EPC valve Engine at high idling PC290-6K 20-239 1 YES Is output pressure of swing holding brake solenoid valve normal? NO Cause Remedy Defective operation of swing holding brake Defective operation of swing holding brake solenoid valve Repair or replace Correct or replace H/O mode G/O mode F/O mode L/O mode 3.0 ± 0.2 MPa (30 ± 2 kg/cm2) 3.0 ± 0.2 MPa (30 ± 2 kg/cm2) 3.0 ± 0.2 MPa (30 ± 2 kg/cm2) 1.5 ± 0.2 MPa (15.5 ± 2.0 kg/cm2)