TROUBLESHOOTING M-CODE 20-241 Condition when normal (voltage, current, resistance) Action by controller when abnormality is detected Problem that appears on machine when there is abnormality • When starting switch is turned ON, keep time switch pressed for 5 seconds to actuated clear function - 1. Service code cannot be cleared 2. Time becomes 00:00 - 1. Service code cannot be cleared 2. Time becomes 00:00 3. Clock does not advance. • Voltage between P01 (7) - chassis Buzzer On: Max. 1V Buzzer OFF: 20 - 30V # When there is a discon- nection, E103 is not displayed and the buzzer does not sound - 1. Buzzer does not sound • Resistance between P11 (male) - P12 (male):
Min 1 (engine started) - 1. If abnormality detection continues, air cleaner clogging caution lamp flashes and buzzer sounds • Resistance between sensor terminal and chassis: Min. 1 M (en- gine at mid-range speed or above) - 1. If abnoramlity detection continues, engine oil pressure caution lamp flashes and buzzer sounds • Resistance between P07 (1) - (2): Min. 3.156 (engine started) - 1. If anbormality detection continues, coolant temperature caution lamp flashes and buzzer sounds 2. If abnormality detection continues, engine speed is reduced to low idling • Voltage between W04 (3) and (5): Max. 3 V to 20 -30 V # Repeats in regular cycle 1. Sets output to relay box to 0 1.
Operation of wiper stops • Voltage between W04 (3) and (5): Max. 3 V to 20 -30 V # Repeats in regular cycle Same as E112 Same as E112 • Resistance of motor: 1.6 1. Sets output to washer motor to 0 1. Operation of window washer stops