Komatsu — eebm001902 a3.pdf

TROUBLESHOOTING M-CODE M-10 When starting switch is turned ON and engine is started, basic check items flash # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. # Check both the alternator system and the engine oil pressure system. a) Alternator system M-10 a) Related electric circuit diagram 20-254 3 YES Does monitoring YES code 43 show a value of greater than 2 100? • Start engine and run NO Is voltage between at mid-range or YES C03 (12) and chassis above 1 normal?

• Set to monitoring Is voltage between code 43 alternator terminal R • Start engine and run NO and chassis normal? at mid-range or above. • 20 -30V • Start engine and run at mid-range or NO above • 20 -30V Cause Remedy Defective engine throttle - pump controller Defective monitor panel Defective contact, or disconnection in wiring harness between alternator terminal R - E08 (2) - C03 (female) (12) Defective alternator Replace Replace Repair or replace Replace