Komatsu — eebm001902 a3.pdf

TROUBLESHOOTING M-CODE M-13, 14 Related electric circuit diagram M-15 Night lighting on monitor panel does not light up (liquid crystal display is normal) # When the front lamp and working lamp light up normaly. M-15 Related electric circuit diagram M38 20-262 YES 1 Is bulb blown, or is there defective contact? 2 YES Does bit (3) of • Remove bulb. monitoring code 49 • Check visually for NO go out? blown bulb 3 YES • Turn starting switch Is voltage between ON. P01 (8) and (12) • Set to monitoring NO normal? code 49 • Turn starting switch NO ON. • Turn light switch ON.

• 20 - 30V Cause Remedy Blown bulb or defective contact of bulb Defective monitor panel Defective contact, or disconnection in wiring harness between P01 (female) (8) - X01 (1) - M38 (female) (1) Replace bulb, or clean (defective contact) Replace Repair or replace