TROUBLESHOOTING M-CODE M-16 Coolant temperature gauge does not rise # If the coolant temperature actually does not rise, check the en- gine system. # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. YES Defective coolant temperature sensor system (see M-26) - When short connector is connected to P07 (fe- male), do level lamps on gauge go up in turn and then all lamps go out? 1 3 YES Defective monitor panal Replace YES Does monitoring code 41 show a value of less than 50? Disconnect P07. Turn starting switch ON.
2 Defective engine throttle - pump controller Replace Is there continuity between C03 (female) (1) and (16) when short connector is connected to P07 (female) Connect short connector to P07 (female) Turn starting switch ON. Set to monitoring code 41. NO NO 4 YES Defective contact, or disconnection in wiring harness between C03 (female) (16) - E08 (11) - P07 (female) (2) Repair or replace Turn starting switch OFF. Disconnect C03 and P07 Is there continuity between C03 (female) (1) and P07 (female) (1)? NO Defective contact or disconnection in wiring harness between C03 (female) (1) - E08 (6) - P07 (female) (1) Repair or replace Turn starting switch OFF, Disconnect C03 and P07.
NO 20-263 Cause Remedy