TROUBLESHOOTING M-CODE M-21 Swing prolix switch is turned ON (prolix), but (swing lock monitor) does not flash # Carry out this troubleshooting only if the swing prolix is actually being actuated. # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. 2 YES Defective monitor panel YES 1 Is bit (6) of monitoring code 21 lighted up? Replace Is voltage between C17 (8) and chassis as shown in table 1? Defective contact or disconnection in wiring harness between C17 (female) (8) and prolix switch (4) Repair or replace Turn starting switch up. Set to monitoring code 21.
NO Turn starting switch ON. NO Defective monitor panel Replace Table 1 M-21 Related electric circuit diagram Engine throttle, pump controller 20-267 Cause Remedy SwingprolixswitchON Max.1V SwingprolixswitchOFF 20-30V