STRUCTURE AND FUNCTION HYDRAULIC PUMP Function LS valve The LS valve detects the load and controls the discharge amount. This valve controls main pump discharge amount Q according to differ- ential pressure L PLS (= PP - PLS ) [[called the LS differential pressure]] (the difference be- tween main pump pressure PP and control valve outlet port pressure PLS ). Main pump pressure PP , pressure PLS [[called the LS pressure]] coming from the control valve out- put, and pressure PSIG [[called the LS selector pressure]] from the proportional solenoid valve enter this valve.

The relationship between dis- charge amount Q and differential pressure L PLS changes as shown in the diagram on the right according to LS selector current isig of the LS-EPC valve. When isig changes between O and 1A, the set pressure of the spring changes according to this and the selector for point for the pump discharge amount changes at the rated central value between 0.74 - 2.2 Mpa (7.5 - 22.5 kg/cm 2 ).

(2/min) 1A 0A 0.74 (7.5) 2.2 (22.5) PC valve When the pump discharge pressure PP1 (self- pressure) and PP2 (other pump pressure) are high, the PC valve controls the pump so that no more oil than the constant flow (in accordance with the discharge pressure) flows even if the stroke of the control valve becomes larger. In this way, it carries out equal horsepower control so that the horsepower absorbed by the pump does not exceed the engine horsepower. In other words, if the load during the operation be- comes larger and the pump discharge pressure rises, it reduces the discharge amount from the pump; and if the pump discharge pressure drops, it increases the discharge amount from the pump.

The relationship between the aver- age of the front and rear pump discharge pres- sure (average discharge amount of F, R pumps ( PP1 + PP2 )/2) and pump discharge amount Q is shown on the right, with the current given to the PC-EPC valve solenoid shown as a param- eter. The controller senses the actual speed of the engine and if the speed drops because of an increase in the load, it reduces the pump dis- charge amount to allow the speed to recover. In other words, when the load increases and the engine speed drops below a set value, the com- mand current to the PC-EPC valve solenoid from the controller increases according to the drop in the engine speed to reduce the pump swash plate angle.

x=0.26A x=0.4A x=0.7A Pump dischare pressure average PP1+PP2)/2 10-25