Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION CLSS During cut-off control Function This function uses the pump pressure sensor, pump controller, and PC valve. When pump dis- charge pressure PP is greater that the set pres- sure, pump discharge amount Q is the mini- mum. Operation 1. If the pump pressure sensor detects that pump discharge pressure PP has become higher than the set pressure, it informs the pump controller. 2. When the pump controller receives this signal, it increases the value of the signal current going to the PC valve and reduces pump discharge amount Q to the minimum (minimum swash plate angle). 3.

When this happens, the oil discharged from the pump passes through the relief valve (low set pressure) and is drained. When power max. is actuated (when cut-off is canceled) Function, operation In the power max. mode, the torque cutt-off sig- nal is not output, so the torque moves along the pump discharge curve. When this happens, the oil discharged from the pump is relieved through the relief valve to maintain the overall balance. 10-56