STRUCTURE AND FUNCTION CLSS Pressure compensation valve 1. Main pump 2. Valve 3. Shuttle valve 4. Piston 5. Spring 6. LS shuttle valve Function during independent operation and at maxi- mum load pressure (during compound operations, when load pressure is higher than other work equip- ment) The pressure compensation valve acts as a load check valve. Operation 1. If the pump pressure (LS pressure) is lower than the load pressure at port C , shuttle valve (3) inside the pressure compensation valve pis- ton (4) moves to interconnect spring chamber E and port C. From this condition, the force of spring (5) acts to move piston (4) and valve (2) in the direction of closing. 10-59