Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION CLSS Function when receiving compensation (during compound operations, when load pressure is lower than other work equipment) The pressure compensation valve is closed by the LS pressure of port D , and the spool meter- in downstream pressure of port B becomes the same as the maximum pressure of the other work equipment. The spool meter-in upstream pressure of port A is the pump pressure, so spool meter-in differential pressure (upstream pressure (pressure of port A ) - downstream pressure (pressure of port B )) becomes the same for all spools that are being operated. Therefore, the pump flow is divided in propor- tion to the area of the meter-in opening. Operation 1.

Spring chamber E is interconnected with port D . Piston (4) and valve (2) are actuated by the LS circuit pressure from the other work equipment at port F in the direction of closing (to the right). In other words, the valve upstream pressure of port B (= spool meter-in downstream pressure) is controlled by the LS pressure. 10-60