STRUCTURE AND FUNCTION CLSS Surface area ratio of pressure compensation valve The condition of the flow division changes according to the ratio of the area of portion A1 and portion A2 of the pressure compensation valve. Area ratio = A2/A1 . When area ratio = 1: Spool meter-in downstream pressure = Max. load pressure, and oil flow is divided in propor- tion to area of opening of spool. When ration is more than 1: Spool meter-in downstream pressure > Max. load pressure, and oil flow is divided in a pro- portion less than area of opening of spool. When ratio is less than 1:
Spool meter-in downstream pressure load pressure, and oil flow is divided in a pro- portion more than area of opening of spool. Pressure compensation valve for service valve The service valve uses a variable type pressure compensation valve, so it can adjust the divi- sion of the oil flow suitably to match the attach- ment installed. 10-61