Komatsu — BEFORE STARTING ENGINE

. OPERATION MACHINE OPERATIONS AND CONTROLS OPERATION MACHINE OPERATIONS AND CONTROLS For details of the method of checking the maintenance 3 - 127 1) The buzzer sounds for approx. 2 seconds, then the monitor or meter lights up f Radiator coolan or approx. 2 seconds. t level monitor (4) onitor (5) sure monitor (6) monitor (7) ging monitor (8) temperature gauge (9) s not light up or the buzzer does not Charge level m Engine oil pres Engine oil level Air cleaner clog Engine coolant If any monitor doe s not light up or the b uzzer does not sound, there is pro bably a failure in the m onitor, so please contact your Koma tsu distributor for repai rs. 2) After approx.

2 se conds, the screen wil l change to the working mode/trav el speed display monitor. Next, it ard screen. temperature gauge (9) temperature monitor (10) ) or (12) mperature gauge (13) mperature monitor (14) will switch to the stand Engine coolant Engine coolant Fuel gauge (11 Fuel level monit Hydraulic oil te Hydraulic oil te mperature monitor (14) 3) If the hydraulic oil t lamp (15) stays immediately for the emperature gauge goes lighted up red, perf item which is lighted u out and caution orm inspection p red. 4) If the maintenanc e interval has passe d, maintenance interval monitor ( 16) lights up for 30 s econds.

Press maintenance switc maintenance imme h F5 (17), check the item, and carry out diately. interval, see "Main in the explanation tenance Selector Switc for each component. h (PAGE 3-41)"