Komatsu — D-2: RELEASING PRESSURE FROM HYDRAULIC CIRCUIT

D-2: RELEASING PRESSURE FROM HYDRAULIC CIRCUIT When removing the hydraulic piping, always release the pressure as follows. 1. Leave the safety lock lever in the FREE position. 2. Remove the cap of the hydraulic tank. 3. Start the engine, run for approx. 10 seconds, then stop the engine. * * * Do not run the engine above 1000 rpm. Keep the control levers at neutral. Raise the safety lock lever and leave it in the FREE position. 4. After stopping the engine, operate the work equip- seconds. ment levers to the end of their stroke within 5 - 6 * Repeat Steps 3 and 4 three times.

When removing the oil filler cap from the hydraulic tank, turn it slowly to release the internal pressure, then remove it. * When the remaining pressure has been released, prevent dust from getting in. install the oil filler cap on the hydraulic tank to * tion. Lower the safety lock lever to the LOCK posi- 73