Komatsu — D-4: FLUSHING WORK EQUIPMENT PIPING

D-4: FLUSHING WORK EQUIPMENT PIPING Purpose This completes the flushing. To remove the dirt and dust which gets into the system during assembly of the attachments, work equipment, Before starting operations, do the following. 1. Check the level of contamination of the oil. and disassembled parts of the body. Flushing is carried out on the machine when it is shipped structions given, the contamination should be with- (If the flushing is carried out according to the in- from the factory. for future reference, measure the level of contami- in the standard, but for safety and to provide data 1. Flush the system. nation.) 1) Run the engine at low idling for 30 minutes.

* When doing this, do not move the control The results of the measurement are not known until later, but if they are not within the standard range, 2) Run the engine at mid-range speed for 30 min- levers in the operator’s compartment. 2. Replace the special flushing element with the stand- carry out flushing again. * When doing this, do not move the control utes. ard parts (07063-01210 x 4), and replace the flush- ing plates (21T-60-13730 x 4) with the valve and levers in the operator’s compartment. strainer. Be sure not to forget this operation. If the 3) Run the engine at high idling and operate the control levers as follows.

element is replaced, replace the O-rings of the return filter case with new parts (%07000-05175 x 4), BOOM RAISE -+ BOOM LOWER --f then tighten the cover. Precaution Be careful not to assemble the element with the bottom + I BUCKET DUMP I + resting on the stepped part at the bottom of the case as Hold the lever at each position for 1 min. - 1 When there is oil inside the filter case, it is particularly shown in Fig. 2. * When operating the control levers, raise the min. 30 sec. Repeat this pattern 4 - 5 times.

so after inserting the element, rotate it by hand and difficult to judge if the element is assembled correctly, hydraulic safety lock and set it to the FREE can be considered that it is installed correctly. check that it rotates smoothly. If it rotates smoothly, it position. 3. Releasing pressure from hydraulic circuit the operator’s cab lights up during flushing, If the filter caution lamp on the monitor inside Release the pressure from hydraulic circuit accord- stop the engine immediately and replace the flushing element. ing to process No. D-2 (See page 73). If no special flushing element is available, re- 01210). place with the standard element (07063- Fig. 1 Correct installation Fig.

2 Incorrect installation 77