Hino — Installation Steps

POWER TAKE OFF 00-21 2. Repeat the “Up” and “Down” operations of the dump lever twice or three times and slowly set the dump lever to the “Up” position as much as possi- ble. 3. Measure the amount of spool extrusion of the oil pump rear and check that it is a specified amount. Amount of spool extrusion: 24 mm (0.945 in) or more NPA0043E Legend 1. Lock nut 2. Double nut 3. Control cable 4. Reference valve NPA0045E Control Cable Adjustment Inspecting the Amount of Spool Extrusion After having installed the control cable, inspect the amount of spool extrusion according to the following procedure. 1. Remove the shift cap tightening bolt of the oil pump rear and remove the shift cap. Legend 1.

Oil pump 2. Spool extrusion 4. Repeat the “Up” and “Down” operations of the dump lever twice or three times and slowly set the dump lever to the “Up” position as much as possi- ble. 5. Measure the amount of spool extrusion of the oil pump rear and check that it is a specified amount. Amount of spool extrusion: less than 2 mm (0.0787 in) Notice: Both amounts of spool extrusion at “Up” and “Down” shall be within a standard value. NPA0044E Legend 1. Shift cap 2. Spool 3. Oil pump rear end 4. Bolt