Doosan DX140R/DX140LCR — Disconnecting the Booster Batteries

IMPORTANT The machine has a 24V (-) negative ground electrical system. Use the same capacity 24V booster batteries when jump starting engine. If the batteries are drained during starting procedures, jump-start engine using auxiliary or booster batteries according to the following procedure: Connecting the Booster Batteries 1 1. Stop engine of the machine on which booster batteries (3, Figure 12) are mounted. RED 2. Connect one end of red cable (1, Figure 12) to the positive (+) terminal of the machine batteries (4), and the other end to the positive (+) terminal of the booster batteries. 3.

Connect one end of black cable (2, Figure 12) to the negative (-) terminal of the booster batteries (3), and then make ground connection to the upper frame (5) of the machine to be started with the other end of black (-) cable (2, Figure 12). When making the last connection to upper frame, be sure to connect the cable end as far away from the machine batteries as possible. DO NOT CONNECT DIRECTLY TO THE NEGATIVE BATTERY TERMINAL. 3 4 BLACK ARO0440L Figure 12 2 5 4. Start the engine. Disconnecting the Booster Batteries 1. Disconnect black negative (-) cable (2, Figure 12) from the machine frame (5) first. 2.

Disconnect the other end of black negative (-) cable (2, Figure 12) from the booster batteries (3). 3. Disconnect red positive (+) cable (1, Figure 12) from the booster batteries (3). 4. Disconnect red positive (+) cable (1, Figure 12) from the machine batteries (4). DX140R/DX140LCR Operation 3-8