Doosan DX140R/DX140LCR — Hydraulic System Warm-up

Hydraulic System Warm-up WARNING AVOID DEATH OR SERIOUS INJURY If a problem or abnormal operation occurs, immediately stop engine. Allow excavator to reach normal operating temperature before starting work, especially in cold weather. The correct operating temperature of the hydraulic oil is 50° - 80°C (120° - 175°F). Make sure to follow the procedures listed here for hydraulic fluid warm-up. 1. Run engine for approximately five minutes set at the middle of the speed range, without a load. HAOB410L Figure 13 2. Move safety lever to "UNLOCK" position. Unlock EX1300566 Figure 14 Lock 3.

Slowly cycle boom, arm and bucket cylinders about five times without a load to circulate the oil through the system. Do this for five minutes. 4. Check for clearance and fully raise the front attachment. Swing clockwise 3 revolutions. Swing counterclockwise 3 revolutions. 5. Travel forward and reverse at low speed for two revolutions of the drive sprocket. Figure 15 Operation 3-9 DX140R/DX140LCR FG014408