Doosan DX140R/DX140LCR — Hydraulic System Warm-up – Cold Weather

Hydraulic System Warm-up – Cold Weather 1. Run engine at "LOW IDLE" (no load) for five minutes (Figure 16). HAOB290L Figure 16 2. Run engine for approximately five minutes set at the middle of the speed range, without a load (Figure 17). HAOB410L Figure 17 3. Move safety lever to "UNLOCK" position. Unlock EX1300566 Figure 18 Lock 4. Slowly cycle boom, arm and bucket cylinders about five times without a load to circulate the oil through the system. Do this for five minutes. Figure 19 DX140R/DX140LCR Operation 3-10 FG014408