Doosan DX140R/DX140LCR — Check for Leaks in Hydraulic System

IMPORTANT Do not fill above "H" mark on sight gauge. Overfilling can result in damage to equipment and oil leaking from hydraulic tank because of expansion. 6. If oil level is above the "H" mark drain oil. A. Stop engine and wait for the hydraulic oil to cool down. B. Drain the excess oil from drain plug (Figure 20) at the bottom of the tank into a suitable container, using a hose connected to the valve. NOTE: Dispose of drained fluids in compliance with all applicable environmental laws and regulations. FG014419 Figure 20 Check for Leaks in Hydraulic System 1.

Perform a daily walk-around inspection to make sure that hoses, piping, fittings, cylinders and hydraulic motors are not showing any signs of leakage. If any is noted, determine the source of the leak and repair. DX140R/DX140LCR Inspection, Maintenance and Adjustment 4-18