Check Fuel Level WARNING 1 AVOID DEATH OR SERIOUS INJURY Use extreme safety precautions while refueling to prevent explosions or fire. Immediately clean up any split fuel. 2 1. At end of each work day, fill fuel tank. Add fuel through fuel fill tube (1, Figure 21). When working at a temperature of 0°C (32°F) or higher, use ASTM No. 2-D or its equivalent. At temperatures below 0°C (32°F) use ASTM No. 1-D or its equivalent. FG014420 Figure 21 2. Make sure that fuel fill hose is grounded to the excavator before fueling begins. 3. Check the amount of fuel in the tank by observing the fuel tank sight gauge (2, Figure 21). NOTE: See "Fluid Capacities" on page 4-9 for capacity. 4.
The excavator may be equipped with the optional battery operated fuel fill pump. The pump assembly is in the hydraulic pump compartment. Put the suction hose of the pump into the fuel resupply tank. Turn the switch in the pump compartment "ON", and the fuel will be pumped into the excavator fuel tank. NOTE: See "Fuel Transfer Pump (Optional)" on page 4-75, for further information. 5. Do not overfill the tank. 6. Securely tighten cap after fueling. NOTE: If breather holes (3, Figure 22) in cap are clogged, a vacuum may form in the tank preventing proper fuel flow to engine. Keep holes in fuel cap clean. 3 3 FG000317 Figure 22 Check for Leaks in Fuel System 1.
Perform an inspection of the engine compartment to verify that fuel system is not leaking. If any is noted, determine the source of the leak and repair. Inspection, Maintenance and Adjustment 4-19 DX140R/DX140LCR