1,000 HOUR / 6 MONTH SERVICE Perform All Daily, 50, 250 and 500 Hour Service Checks Grease Swing Reduction Device 1. Park machine on firm and level ground. Lower the front attachment to the ground and stop engine. 2. Remove air vent plug (1, Figure 77) from swing reduction device. 1 Figure 77 FG006316 3. Press grease fitting and inject grease with the grease gun on the marked point (2, Figure 78). 4. Install air vent plug (1, Figure 77) in swing reduction device. 2 FG009576 Figure 78 Change Air Breather Filter 1 1. Park machine on firm and level ground. Lower the front attachment to the ground and stop engine. 2 2. Lift the breather cap(2.
Figure 79) slightly to release the internal pressure. 3. Unscrew the bolt (1, Figure 79) and take off the breather cap (2, Figure 79). 3 4. Change a filter cartridge (3, Figure 79) and assemble the breather cap by tighting the bolt. NOTE: Used filter should always be disposed of according to local regulations. NOTE: When the machine is operated under dusty work sites, the air breather filter needs to be cleaned or replaced on a regular basis even before the expected replacement date. FG013207 Figure 79 Inspection, Maintenance and Adjustment 4-47 DX140R/DX140LCR