Doosan DX140R/DX140LCR — Change Air Breather Filter

Replace Hydraulic Oil Return Filter NOTE: Change hydraulic oil return filter after first 250 hours of operation or rebuild, and every 1,000 hours thereafter. NOTE: If return filter clogged warning light (Figure 80) on instrument panel comes "ON" the return filter must be serviced. FG013832 Figure 80 WARNING 1 AVOID DEATH OR SERIOUS INJURY The hydraulic oil will be hot after normal machine operation. Allow the system to cool before attempting to service any of the hydraulic components. 3 The hydraulic tank is pressurized. Loosen the hydraulic breather cap slightly to allow the pressurized air to vent.

After the pressure has been released, it is safe to remove either the fill cap or service covers or drain water from the tank. 2 FG014437 Figure 81 IMPORTANT 4 3 6 Make sure to clean any dirt or water from the top of the hydraulic tank, especially around the fill port and filter ports. 7 5 1. Park machine on firm and level ground. Lower the front attachment to the ground and stop engine. 8 2. Lift the breather cap (1, Figure 81) slightly to release the internal pressure. 3. Remove bolts (2, Figure 81) and service cover (3). Remove spring (4), valve (5) O-ring (6), and bypass strainer (7), and then filter (8). 4. Remove filter and discard. NOTE:

Used filter should always be disposed of according to local regulations. FG000761 5. Install new filter and a new O-ring. Install bypass strainer, valve and spring. Install service cover plate. Figure 82 6. Tighten the breather cap (1, Figure 81). 7. Run engine for ten minutes at low idle to purge air from circuit. 8. Check level in hydraulic oil tank (See page 4-17). Add oil if necessary. DX140R/DX140LCR Inspection, Maintenance and Adjustment 4-48