Komatsu — AIR CLEANER ELEMENT-CHECK/CLEAN/REPLACE

MAINTENANCE MAINTENANCE PROCEDURE WHEN REQUIRED Air Cleaner Element - Check/Clean/Replace WARNING If inspection, cleaning, or maintenance is carried out with the engine running, dirt will get into the engine and the engine will suffer damage. Always stop the engine before carrying out these opera- tions. When using compressed air, there is danger that dirt may be blown around and cause serious injury. Always use safety glasses, dust mask, and other protective equipment. Machines Equipped With Singel Element Checking Whenever the red piston in dust indicator (1) appears, clean the air cleaner element.

NOTICE Do not clean the air cleaner element before the red piston in dust indicator (1) appears. If the air cleaner element is cleaned frequently before the red piston in the dust indicator appears, the air cleaner cannot provide the proper performance and the cleaning efficiency is lowered. Cleaning the element 1. Open the engine food on the rear of the machine, remove wingnut (2) and take out element (3) . To prevent entry of dirt and dust, cover the air connector side of the rear end of the air cleaner with a clean cloth and adhesive tape. 2. Clean interior of the air cleaner body. 3.

Direct dry compressd air (less than 0.69MPa (7 kgf/cm 2 , 99.4 PSI)),to element 3 from inside along its folds, then direct it from outside along its folds and again from inside. 1) Remove one seal from the element whenever the element has been cleaned. 2) Replace the element which has been cleaned 6 times repeatedly or used throughout a year. 3) Replace the element when the dust indicator red pis- ton appears soon after installing the cleaned element even though it has not been cleaned 6 times. 4-19