MAINTENANCE MAINTENANCE PROCEDURE Hydraulic System - Bleed Air For details, see "STARTING ENGINE (PAGE 3-47)". If it is necessary to refer to the items for starting the engine, moving the machine off, steering, or stopping, see the OPERATION section. 1. Bleeding air from pump 1) Loosen air bleed plug (1) installed to the drain port and check that oil oozes out (air bleeding is com- pleted). 2) After completion of the air bleeding operation, tighten the air bleed plug. NOTICE If the pump is run when the pump case is not full of oil, there will be abnormal generation of heat, and this will lead to premature failure of the pump. 2.
Bleeding air between pump and hydraulic tank 1) Start the engine and maintain it at a mid-range speed (1650 rpm). For details, see "STARTING ENGINE (PAGE 3-47)". 2) Operate the work equipment slowly for approx. 5 minutes to bleed the air. NOTICE If the engine is run at high speed without bleeding the air between the pump and hydraulic tank, there will be abnormal generation of heat, and this will lead to premature failure of the pump. 3. Bleeding air from cylinders 1) Run the engine at a mid-range speed (1650rpm) and extend and retract the cylinders 4 to 5 times to a point 100 mm(3.9in) from the end of the stroke.
(Be careful not to operate to the end of the stroke.) 2) Next, operate each cylinder 3 to 4 times to the end of its stroke. 3) Finally, operate each cylinder 4 to 5 times to the end of its stroke to completely remove the air. NOTICE If the engine is run immediately at high speed or the cylinder is operated to the end of its stroke, the air inside the cylinder may cause damage to the piston packing. 4-47