Komatsu — HYDRAULIC SYSTEM-BLEED AIR

MAINTENANCE PROCEDURE MAINTENANCE 4. Bleeding air from swing motor (only after draining oil from swing motor case) 1) Run the engine at low idling, Loosen air bleeding plug (1) and check that oil oozes out from air bleed- ing plug (1). NOTICE When doing this, do not operate the swing. 2) If no oil oozes out, stop the engine, remove air bleeding plug (1), then fill the motor case with hydraulic oil. 3) After completing the air bleed operation, tighten air bleeding plug (1). 4) Run the engine at low idling, and slowly swing the upper structure at least 2 times uniformly to the left and right. NOTICE If the air is not bled from the swing motor, the motor bear- ings may be damaged. 5.

Bleeding air from travel motor (only when oil inside travel motor case has been drained) 1) Run the engine at low idling, remove hose (1) from port C, then when the oil has flowed out, tighten it again. 4-48