MAINTENANCE MAINTENANCE PROCEDURE EVERY 5000 HOURS MAINTENANCE Maintenance for every 50, 100, 250, 500 and 1000 hours service should be carried out at the same time. Change Oil In Hydraulic Tank, Clean Strainer WARNING The parts and oil are at high temperature after the engine is stopped, and may cause serious burns. Wait for the temperature to go down before changine the oil in the hydraulic tank. When the oil filler cap is removed, oil may spurt out, so turn the cap slowly to release the pressure before removing the cap. NOTICE If the machine is equipped with a hydraulic breaker, the hydraulic oil will deteriorate much faster than dur- ing normal bucket operations.
For details, see "MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER (PAGE 4-17)" when carrying out maintenance. Container to catch drained oil: min. 57 liters capacity Refill, capacity: 57 liters (15.05 US gal, 12.54 UK gal) Prepare a handle for the socket wrench set. 1. Swing the upper structure so that the drain plug under the hydraulic tank comes at the middle of the left or right track. 2. Retract the arm and bucket cylinders to the end of the stroke, then lower the boom and put the teeth in contact with the ground. 3. Lower the blade to the ground. (Only machines with blade specification) 4. Lock the safety lock lever and stop the engine. 4-71