Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

MBE 4000 SERVICE MANUAL [c] Using the engine cranking tool (J 46167 or 407 589 00 63 00), turn the flywheel in a counterclockwise direction (as viewed from the flywheel end). NOTE: The dial gauge will show the highest reading when the valve is completely open. [d] When the valves are completely open, read off the value on the dial gauge. If the intake valve lift reaches at least 11.546 mm (0.4546 inch) at its highest point, the intake valves are lifting OK. Check the exhaust valves.If the intake valve lift fails to reach 11.546 mm (0.4546 inch) at its highest point, remove the camshaft and inspect the cams for wear. Refer to section 1.22.1. NOTE:

If the gauge reading fails to reach 11.546 mm (0.4546 inch), be sure the valves were completely open. The dial gauge will show the highest reading when the valve is completely open. 6. Check the lift on the exhaust valves. See Figure 1-108. 1. Dial Gauge 4. Pushrod 2. Gauge Holder 5. Exhaust Valve 3. Exhaust Rocker Arm Figure 1-108 Checking Valve Lift, Exhaust Valves [a] Turn the flywheel in a counterclockwise direction until both valves are closed. All information subject to change without notice. 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 1-141