Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

2.6 PROTECTIVE SLEEVE 1. Disconnect the electrical connector. See Figure 2-17. 1. Crank Angle Position Sensor 3. Flywheel Housing (Timing Case) 2. Electrical Connector Figure 2-17 Crank Angle Position Sensor Installation 2. Remove the sensor from the access hole in the flywheel housing. 3. Install a new sensor in the flywheel housing. 4. Connect the electrical connector. NOTE: Be sure that the correct electrical connector is connected to the sensor. All information subject to change without notice. 2-28 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION