Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

MBE 4000 SERVICE MANUAL 5. Check all the test values for the main valve listed in Table 4-5. If any of the values is not met, replace the thermostat. Table 4-5 Thermostat Test Values [a] At the temperature of 185 F (85 C), check that the main valve has started to open. [b] At the opening temperature of 203 F (95 C), check that the main valve is fully open. [c] Check the minimum lift of the main valve at the opening temperature. 6. Check all the test values for the short circuit valve listed in Table 4-5. If any of the values is not met, replace the thermostat. [a] At the temperature of 198 F (92 C), check that the short circuit valve is fully closed.

[b] Check the minimum lift of the short circuit valve at the closing temperature. 7. Install the original or replacement thermostat(s), as necessary, the upper coolant hose inlet, and O-ring(s) on the coolant pump, as removed. 8. Fill the engine with coolant, as removed, and check for leaks and proper operation. All information subject to change without notice.

6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 4-29 Description Temperature Distance mm (inch) Main Valve Starts To Open 177 to 185 F (81 to 85 C) — Main Valve Fully Open 203 F (95 C) — Main Valve Minimum Lift — 8 mm (0.3 inch) Short Circuit Valve Fully Closed 198 F (92 C) — Short Circuit Valve Minimum Lift — 6 to 7.5 mm (0.24 to 0.295 inch)