Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

4.6 EGR THERMOSTAT HOUSING 4.6 EGR THERMOSTAT HOUSING The thermostat for the EGR engine has the same removal, installation, and checking instructions as for the non-EGR engine (refer to section 4.5), but the thermostat housing cover is different by design to accommodate the EGR modulated control valve mounting. See Figure 4-17. 1. EGR Modulated Valve Mounting Holes 2. Thermostat Housing Cover Mounting Holes Figure 4-17 EGR Thermostat Housing Cover 4.6.1 EGR Thermostat Housing Cover Removal Remove the EGR thermostat housing cover as follows: 1. Remove the four bolts that attach the EGR modulated control valve to the housing cover and remove the valve. 2.

Remove the three thermostat housing cover mounting bolts. 3. Remove the two bolts that attach the reed valve housing bracket to thermostat cover. Remove bracket. 4. Remove any other hose or fitting connections. 4.6.2 EGR Thermostat Housing Cover Installation Install the EGR thermostat housing cover as follows: All information subject to change without notice. 4-30 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION