Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

MBE 4000 SERVICE MANUAL 1. Attach the thermostat housing cover to the thermostat housing using the three mounting bolts. Install the first bolt where heavy arrow is pointing in graphic. See Figure 4-18. Torque to 30 N·m (22 lb·ft). 1. EGR Modulated Valve Mounting Holes 2. Thermostat Housing Cover Mounting Holes Figure 4-18 EGR Thermostat Housing Cover Installation 2. Install EGR modulated valve to thermostat housing cover using four bolts. 3. Attach reed valve housing bracket to thermostat cover. 4. Install any other hose or fitting connections. All information subject to change without notice. 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 4-31