MBE 4000 SERVICE MANUAL 8. Insert the connecting membrane in the EGR cooler boss using industrial petroleum grease and push the EGR coolant outlet pipe onto the cooler. See Figure 7-31. 1. Coolant Outlet Pipe Bolts 4. EGR Coolant Outlet Pipe 2. Coolant Vent Line 5. Coolant Outlet Pipe Bracket 3. Membrane Figure 7-31 Installation of Coolant Vent Line and Coolant Outlet Pipe 9. Attach front sheet metal support-to-cooler support using two M8 x 12 mm bolts. Torque to 25 N·m (19 lb·ft). 10. Install the bolt to the coolant outlet pipe bracket. Torque to 35 N·m (26 lb·ft). See Figure 7-31. 11. Install coolant vent line. Torque to 25 N·m (19 lb·ft). 12.
Install the reed valve-housing bracket to the thermostat housing with the three mounting bolts. Torque to 25 N·m (19 lb·ft). See Figure 7-32. 13. Install the EGR air temperature sensor into reed valve housing flange. Torque to 25 N·m (19 lb·ft). Using plastic ties, attach remainder of sensor to reed valve-housing bracket. See Figure 7-32. All information subject to change without notice. 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 7-39