MBE 4000 SERVICE MANUAL * Threads may have residual oil, but will be dry to the touch. Use one of the previous tables if either the male or female threads (bolt and nut) are plated or lubricated. Coat all plated and unplated fasteners with oil before installation. Table 8 Torque Specifications Table Five All information subject to change without notice. 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 39 Torque Values for Metric Thread Fasteners with Lubricated* or Plated Threads† Thread Diameter-Pitch Grade 8.8 Bolt Grade 8 Nut Grade 10.9 Bolt Grade 10 Nut Torque:
lb·ft (N·m) M6 5 (7) 7 (9) M8 M8 x 1 12 (16) 13 (18) 17 (23) 18 (24) M10 M10 x 1.25 24 (33) 27 (37) 34 (46) 38 (52) M12 M12 x 1.5 42 (57) 43 (58) 60 (81) 62 (84) M14 M14 x 1.5 66 (89) 72 (98) 95 (129) 103 (140) M16 M16 x 1.5 103 (140) 110 (149) 148 (201) 157 (231) M18 M18 x 1.5 147 (199) 165 (224) 203 (275) 229 (310) M20 M20 x 1.5 240 (282) 213 (313) 288 (390) 320 (434) M22 M22 x 1.5 283 (384) 315 (427) 392 (531) 431 (584) 1–8 1–12 1–14 580 (786) 635 (861) 650 (881) 820 (1112) 900 (1220) 915 (1241)