Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

MBE 4000 SERVICE MANUAL 7.6 EPV (ELECTRONIC PROPORTIONAL VALVE) AND WABCO ® AIR SOLENOID VALVE Listed in Table 7-4 is each proportional valve listed and the component it activates. Table 7-4 Proportional Valve Chart 7.6.1 Removal of EPV Valve and Wabco Air Solenoid Valve Perform the following steps to remove the EPV valve, Wabco air solenoid valve and all the corresponding connections: 1. Disconnect wiring harness from the EPV valve and the Wabco solenoid valve. All information subject to change without notice.

6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 7-51 Proportional Valve Component PV1 Exhaust flap enable + EGR shutoff valve or boost control = wastegate valve (Turbobrake) PV2 EGR control valve PV3 Fan PV4 Fan PV5 CTV (Constant Throttle Valve) PV6 Turbobrake sliding sleeve + EGR shutoff valve