7.6 EPV (ELECTRONIC PROPORTIONAL VALVE) AND WABCO ® AIR SOLENOID VALVE PERSONAL INJURY To avoid injury from the sudden release of a high-pressure hose connection, wear a face shield or goggles. 5. Install inlet and outlet connections at EPV pressure regulating valve. Torque to 15 N·m (11 lb·ft). NOTICE: Avoid friction on compressed air pipe traveling under the EPV valve or potential damage to engine could result. 6. Install smaller hollow screw below larger hollow screw, securing connection. Torque to 15 N·m (11 lb·ft). 7. Fit the pipe between inlet connection installed at EPV valve and turbo brake actuator. 8. Connect wiring harness to EPV valve and Wabco valve.