Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

MBE 4000 SERVICE MANUAL 8. Remove the two M14 x 25 mm bolts that hold the EPV/solenoid valve bracket to the block. 7.6.2 Installation of EPV Valve and Wabco Air Solenoid Valve Perform the following steps to install the EPV valve, Wabco air solenoid valve and all corresponding connections: 1. Install the EPV/solenoid valve bracket to the block with two M14 x 25 mm bolts. Torque to 100 N·m (74 lb·ft). 2. Mount the Wabco solenoid valve on right side of bracket using two M8 x 50 mm bolts. Apply 25 N·m (19 lb·ft) tightening torque. See Figure 7-43. 1. EPV (Electronic Proportional Valve) 6. Hollow Screw 2. Turbo Brake Actuator 7. Small Hollow Screw 3. Electric Wiring Harness Terminals 8.

EPV Valve Inlet 4. Wabco Valve 9. EPV Valve Outlet (hidden) 5. Solenoid Valve Mounting Bolts 10. EPV Valve Mounting Bolts Figure 7-43 Installing the EPV Valve / Wabco Solenoid Valve 3. Mount the EPV valve on left side of bracket using two M8 x 50 mm bolts. Torque to 25 N·m (19 lb·ft) tightening torque. 4. Install large hollow screw in threaded connection. Torque to 50 N·m (37 lb·ft). See Figure 7-43. All information subject to change without notice. 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 7-53