Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

MBE 4000 SERVICE MANUAL 14.1 PREPARING ENGINE FOR STORAGE When an engine is to be stored for a period of time, special precautions should be taken to protect the interior and exterior of the engine. 14.1.1 Cleaning the Engine Please follow the equipment manufacturer's operating instructions for using high-pressure cleaning equipment. Information on suitable cleaning and protective products is available from any authorized dealer. NOTICE: To prevent damage to engine components during the cleaning process, keep the water moving at all times. Never direct water onto electrical components, plug connectors, seals or flexible hoses.

Comply with the minimum working distance between the high-pressure nozzle and the surface being cleaned: Approximately 28 inches (700 mm) for circular pattern jets Approximately 12 inches (300 mm) for 25-degree flat jets and dirt cutters 14.1.2 Cleaning the Cooling System Clean the cooling system as follows: NOTE: Collect the used coolant, cleaning solutions, and washing liquids. Dispose of them in accordance with applicable laws regarding the protection of the environment. All information subject to change without notice. 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 14-3