Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

1.2 CYLINDER HEAD [d] Place the straightedge diagonally across the cylinder head. Repeat the procedure above. 6. Check the cylinder head contact surface for parallelism, at each corner. See Figure 1-9. If the four measurements deviate by more than 0.1 mm (0.004 inch), machine the cylinder head. Figure 1-9 Measuring Cylinder Head Parallelism [a] Rest the cylinder head on a flat surface, with the contact surface exposed (bottom face up). NOTE: Make sure the head is level before going on with this check. [b] Install a dial gauge so that the feeler touches the contact surface with some preload. [c] Fasten the dial gauge and adjust the scale to "0" (zero). [d] Check the reading on the dial gauge.

If the reading is larger than 0.1 mm (0.004 inch), machine the cylinder head. [e] Repeat this procedure at each spot marked by an arrow (each corner of the cylinder head). All information subject to change without notice. 1-16 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION