Komatsu — CHECKS BEFORE STARTING

OPERATION MACHINE OPERATIONS AND CONTROLS CHECK FUEL LEVEL, ADD FUEL WARNING When adding fuel, never let the fuel overflow. This may cause a fire. If any fuel is spilled, wipe it up com- pletely. Never bring flames near fuel because it is highly flammable and dangerous. 1. Open fuel filler cap (F) of the fuel tank. 2. When fuel filler cap (F) is opened, float gauge (G) will rise according to the fuel level. Check that the fuel tank is full. Check by looking into the tank and by using float gauge (G). 3. If the tank is not full, add fuel through the fuel filler until float gauge (G) rises to the maximum position. Fuel tank capacity:

400 liters (105.68 US gal) Position of tip of float gauge (G) when tank is full: Approx. 50 mm (2 in) from top surface of fuel tank 4. After adding fuel, push float gauge (G) straight down with fuel filler cap (F). Be careful not to get float gauge (G) caught in the tab of fuel filler cap (F), and tighten fuel filler cap (F) securely. REMARK If breather hole (1) on the cap is clogged, the pressure in the tank will drop and fuel will not flow. Clean the hole from time to time. DRAIN WATER, SEDIMENT FROM FUEL TANK 1. Open the pump room door on the right side of the machine. 2. Put a container to catch the drained fuel under drain hose (1). 3.

Open drain valve (2) at the rear of the hydraulic tank and drain the sediment and water accumulated at the bottom of the tank together with the fuel. 4. When clean fuel comes out, close drain valve (2). 5. Close the pump room door on the right side of the machine. 3-61